便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)是(shi)壹(yi)種(zhong)高靈(ling)敏度(du)智(zhi)能(neng)化的便(bian)攜式(shi)儀器
更(geng)新時(shi)間(jian):2019-06-26 點(dian)擊次(ci)數(shu):3689次
便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)是(shi)壹(yi)種(zhong)高靈(ling)敏度(du)智(zhi)能(neng)化的便(bian)攜式(shi)儀器
便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)每(mei)個脈(mai)沖(chong)都是電(dian)子探(tan)測並(bing)進行(xing)運算(suan),由(you)於(yu)放(fang)射能(neng)的任意狀態而每(mei)分鐘(zhong)都在變(bian)化,以過去壹(yi)段(duan)時(shi)間(jian)內(nei)的平(ping)均值表(biao)示更(geng)加(jia)準(zhun)確(que),而且(qie)這(zhe)段(duan)時(shi)間(jian)越(yue)長(chang)數(shu)據越(yue)準(zhun)確(que)。
便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)主(zhu)要用(yong)於測量(liang)物體表(biao)面(mian)的αβ放射性(xing)表(biao)面(mian)汙染(ran)水平(ping),也可測量(liang)γ輻射劑量(liang)率,對(dui)低水平(ping)輻射靈敏,對(dui)汙染(ran)的墻壁(bi)、桌(zhuo)面、地(di)板(ban)及(ji)工(gong)作人(ren)員(yuan)的身體部位(wei)和工(gong)作服(fu)等(deng)αβ汙染(ran)具有良(liang)好的測量(liang)特性(xing)。便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)適用(yong)於(yu)核(he)能(neng)利用(yong)的各(ge)廠(chang)礦、車(che)間(jian)、實驗室(shi)、核(he)設施退役、核電(dian)站、核以及(ji)核(he)防(fang)護(hu)部門等(deng),可作為應核急測量(liang)箱(xiang)配套設備(bei)。具有大(da)面積、高靈(ling)敏、多(duo)功(gong)能(neng) 、易操作的特點(dian)。
儀器測量(liang)讀(du)數(shu)由帶背(bei)光(guang)點(dian)陣液晶顯(xian)示器給出,對α和β、γ測量(liang)可切換(huan)顯(xian)示,測量(liang)時由手(shou)柄按鍵操作,並(bing)設置手動(dong)清(qing)零計數(shu)和自動(dong)清(qing)零計數(shu)兩種工(gong)作方(fang)式(shi),方便(bian)使用,易於控制。便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)具有超閾(yu)值報警(jing)、超(chao)量(liang)程報警(jing)、電(dian)池欠(qian)壓(ya)報警(jing)等(deng)功(gong)能(neng),根(gen)據核(he)快速應急反應(ying)監(jian)測技(ji)術(shu)要求(qiu),專(zhuan)門為廢舊材料(liao)輻射汙染(ran)檢(jian)測、以及(ji)核(he)醫(yi)學(xue)、分子生物實驗室(shi)、核(he)材料(liao)運輸及(ji)其它(ta)存(cun)在(zai)α、β表(biao)面(mian)沾(zhan)汙和(he)γ輻射的方面(mian)而設(she)計,是(shi)壹(yi)種(zhong)高靈(ling)敏度(du)智(zhi)能(neng)化便(bian)攜式(shi)儀器。
便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)能(neng)量(liang)補償型(xing)端窗(chuang)式(shi)GM管(guan)探(tan)頭(tou)(美(mei)國進口),性(xing)能(neng)優(you)良(liang),壹(yi)機雙(shuang)用(yong);功(gong)能(neng)全(quan)面,滿(man)足設置報警(jing)閾(yu)值、單(dan)位(wei)切換(huan)及(ji)儀(yi)器自檢(jian)等(deng)多種(zhong)需(xu)求(qiu);完(wan)善(shan)的軟(ruan)件設(she)計(ji)及(ji)處(chu)理(li),使整(zheng)機性(xing)能(neng)更為出眾;的表(biao)面(mian)貼(tie)裝(zhuang)技(ji)術(shu),領國(guo)內核(he)儀(yi)器之(zhi)先河;人性(xing)化結構設(she)計,使儀器輕巧結實,便(bian)於攜帶(dai)、操作及(ji)測量(liang),工(gong)藝(yi),外(wai)觀(guan)漂(piao)亮大(da)方。
便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)按照預(yu)先校(xiao)準(zhun),通(tong)過自動(dong)死時(shi)間(jian)的校(xiao)正,可(ke)獲(huo)得(de)非常(chang)寬(kuan)的動(dong)態範(fan)圍,上限達到(dao)每(mei)分鐘(zhong)999,000的計數(shu)值;它(ta)*的平(ping)滑(hua)讀(du)數(shu)函數(shu)可讓儀器在(zai)保持很(hen)小的偏(pian)差和(he)快(kuai)的響應時間(jian)下平(ping)滑(hua)地(di)讀(du)數(shu)。便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)利(li)用粉(fen)塵采(cai)樣(yang)器檢(jian)定(ding)裝(zhuang)置(zhi)或(huo)皂沫流(liu)量(liang)計,連(lian)接在(zai)采(cai)樣(yang)頭(tou)進氣口(kou)上測試(shi),轉子流量(liang)計的示值跟皂沫流(liu)量(liang)計測得(de)的流量(liang)誤(wu)差應小於(yu)±2.5%。
便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)負載(zai)能(neng)力采(cai)樣(yang)頭(tou)內裝(zhuang)好濾(lv)膜,啟(qi)動(dong)粉塵(chen)采(cai)樣(yang)器,將(jiang)采(cai)樣(yang)流(liu)量(liang)調節到(dao)規(gui)定(ding)點,將(jiang)三(san)通(tong)、壓(ya)力計、截(jie)止(zhi)閥連(lian)接在(zai)采(cai)樣(yang)頭(tou)上,然(ran)後逐步(bu)關(guan)閉(bi)閥(fa)門,使采(cai)樣(yang)流(liu)量(liang)下降(jiang)原流(liu)量(liang)的5%時,讀(du)取(qu)此(ci)時檢(jian)定(ding)裝(zhuang)置(zhi)或(huo)液體壓(ya)力計的讀(du)值,即為負載(zai)能(neng)力值。用戶(hu)可(ke)利(li)用(yong)秒(miao)表(biao)進行(xing)檢測,根(gen)據規(gui)程要(yao)求(qiu)在(zai)5分鐘(zhong)內誤(wu)差不(bu)得(de)大(da)於1.0秒(miao),由(you)於(yu)便(bian)攜式(shi)表(biao)面(mian)汙染(ran)儀(yi)采(cai)用(yong)石(shi)英(ying)晶振(zhen),精度(du)很(hen)高,壹(yi)般(ban)可(ke)不(bu)作檢(jian)驗。